A modular DC bus bar, with locations for four DC fuses. It will monitor the status of each fuse, and indicate its condition with a LED on the front. Part of the modular Lynx distribution system.
Contains a positive and negative bus-bar and provides a connection for 4 individual DC equipment circuits, loads or DC groups. It has a space for individual DC fuses per DC group.
There is an optional feature of an LED for each fuse to indicate if fuse is blown.
If you wish to use the fuse indication LEDs on the Lynx Distributor, it also requires a connection to a Lynx Shunt. The Lynx Shunt contains the necessary wide input (8 to 70VDC) power supply to output the required 5V (4.5V-5.5V) power requirement of the Lynx Distributor circuit board.
Have you tried Victron Energy Support? Victron Energy offers a wide variety of support levels from software updates, manuals, system schematics, datasheets, and much more. Please be aware that a Victron Energy product is always part of a bigger system. Be sure to check and pay attention to all of the components.
Looking for additional support for your Victron Energy product? Solarflexion offers tech support services too, if you're looking for additional help. Our standard service fees do apply. See our service rates for more details. Please have the following information ready: